Description
Frequency modulated continuous wave (FMCW) is adopted for radar level instrument (80G). The antenna transmits the high frequency and frequency modulated radar signal.
The frequency of the radar signal linearly increases. the transmitted radar signal is reflected by dielectric to be measured and received by antenna. at the same time, the difference between the frequency of transmitted signal and that of the received signal is proportional to the measured distance.
Therefore, the distance is calculated by the spectrum derived from the analog-to-digital conversion frequency difference and the fast fourier transform (FFT)
Advantages
(1) Based on self-developed milimeter-wave radio frequency chip to achieve a more compact radio frequency architecture.
(2) Higher signal-to-noise ratio, almost unaffected by level fluctuations.
(3) The measurement accuracy is millimeter-level accuracy (1mm), which can be used for metrology-level measurement.
(4) The measurement blind area is small, and the effect of measuring the liguid eve of small storage tanks is better.
(5) The beam angle can reach 3 and the energy is more focused,effectively avoiding false echo interference.
(6) High frequency signal, can effectively measure the level of medium with low dielectric constant (e>1.5).
(7) The antenna adopts PTFE lens, which is effective anti-corrosion and anti-hanging material.

Application
Measure the level of solid particles, chemical liquid tank, oil tank and process containers.
1.Radar level meter is working based on electromagnetic wave. So it could have max 120m measure range.
2.Compared with other type level meter, 80G radar level meter could measure different kinds of oil, chemical liquids, solid powder,and many other mediums.
3. 80G radar level meter could work in harsh working condition. It won’t be affected by temperature, pressure and humidity. With PTFE horn, it even could work in corrosive condition, such as acid liquid.
4.Customer also could choose different connection methods, such as flange, thread, bracket.
Table 1 : Technical Parameters
| Picture | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Model | QTRD-81 | QTRD-82 | QTRD-83 | QTRD-84 | QTRD-85 | QTRD-86 | QTRD-87 |
| Application | Slightly corrosive liquid, stirring, condensation |
Slightly corrosive liquid, stirring, condensation |
Strong dust, Solid, Block, Powder | Strong corrosive liquid, stirring, condensation |
High temperature, strong corrosive liquid, stirring, condensation |
Strong corrosive liquid, stirring, condensation |
High temperature and high pressure liquid and solid |
| Process Connection |
1.5″ Thread, Flange | 3.5″ Thread, Flange | Flange with purging | Flange | Flange | Flange | Flange |
| Standard Process Temperature |
-30~+100℃ | -30~+80℃ | -30~+100℃ | -30~+75℃ | -40~+200℃ | -30~100℃ | -40~ +1000℃ |
| Process Pressure | -0.1~0.3 MPA | -0.1~0.3 MPA | -0.1~0.3 MPA | -0.1~0.1 MPA | -0.3~2 MPA | -0.1~2 MPA | -0.5~3 MPA |
| Beam Angle | 8° | 3° | 3° | 5° | 5° | 8° | 3° |
| Measuring Range | 10m, 20m, 30m | 10m, 20m, 30m, 80m, 120m |
10m, 20m, 30m, 80m, 120m |
10m, 20m, 30m, 80m, 120m |
10m, 20m, 30m, 80m, 120m |
10m, 20m, 30m | 10m, 20m, 30m, 80m, 120m |
| Accuracy | ±1 mm(≤30mm) ±3 mm(≥30mm) | ±5 mm | ±1 mm(≤30mm), ±3 mm(≥30mm) | ||||
| Resolution | ±1mm (Under ideal laboratory condition ) | ||||||
| Wetted Parts | PTFE | Carbon steel, SS304, SS316 | |||||
| Blind zone | 0.15m for 35m, 0.4m for 85m, 0.6m for 120m | ||||||
| Frequency | 76~81GHz, FM scanning frequency width 5GHz | ||||||
| Ambient Temperature |
-30~+70℃ | ||||||
| Shell Material | Cast Aluminium, SS304, SS316 | ||||||
| Power Supply | 18~28 VDC, 85~865 VAC | ||||||
| Signal Output | Two-wire / four-wire 4~20mA, HART / RS485 Modbus / Bluetooth | ||||||
| Structurer | Compact, remote | ||||||
| Ex-proof | Ex d IIC T6 Gb optional | ||||||
| Protect Grade | IP67 | ||||||
| Language | English, Spanish, Russian, Portuguese, Korean | ||||||
Table 2 : Model Selection
| QTRD-87 | X | X | X | X | X | X | X | X | |
| Measuring Range | 10m | 10 | |||||||
| 20m | 20 | ||||||||
| 30m | 30 | ||||||||
| 80m | 80 | ||||||||
| 120m | 120 | ||||||||
| Process Connection | DN80 flange | 1 | |||||||
| DN100 flange | 2 | ||||||||
| DN125 flange | 3 | ||||||||
| DN150 flange | 4 | ||||||||
| Medium Temperature | 18~28 VDC | D | |||||||
| 85~265 VAC | A | ||||||||
| Power Supply | -40~1000℃ | T | |||||||
| Signal Output | Two-wire 4~20 mA + HART | H | |||||||
| 4~20 mA + RS485 Modbus | RS | ||||||||
| Bluetooth | B | ||||||||
| Shell Material | Cast Aluminium (standard) | A | |||||||
| SS304 | 4 | ||||||||
| SS316 | 6 | ||||||||
| Explosion Proof | Without | N | |||||||
| Ex d IIC T6 Gb | E | ||||||||
| Structure | Compact | C | |||||||
| Remote with 10m cable | R | ||||||||
Remark: If you require process connection in flange type, please indicate flange standard before order.
Drawing:
.png)




.png)
.png)
.png)
.png)
.png)
.png)
.png)